2-Ethoxyethanol |
Synonyms & Trade Names Cellosolve®, EGEE, Ethylene glycol monoethyl ether |
CAS No. 110-80-5 |
RTECS No. KK8050000 |
DOT ID & Guide 1171 127 |
FormulaC2H5OCH2CH2OH |
Conversion 1 ppm = 3.69 mg/m3 |
IDLH 500 ppm See: 110805 |
Exposure Limits NIOSH REL: TWA 0.5 ppm (1.8 mg/m3) [skin] OSHA PEL: TWA 200 ppm (740 mg/m3) [skin] |
Measurement Methods NIOSH 1403; OSHA 53 , 79 See: NMAM or OSHA Methods |
Physical Description Colorless liquid with a sweet, pleasant, ether-like odor. |
MW: 90.1 |
BP: 275°F |
FRZ: -130°F |
Sol: Miscible |
VP: 4 mmHg |
IP: ? |
Sp.Gr: 0.93 |
Fl.P: 110°F |
UEL(200°F): 15.6% |
LEL(200°F): 1.7% |
|
|
| Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F. |
Incompatibilities & Reactivities Strong oxidizers |
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact |
Symptoms In animals: irritation eyes, respiratory system; blood changes; liver, kidney, lung damage; reproductive, teratogenic effects |
Target Organs Eyes, respiratory system, blood, kidneys, liver, reproductive system, hematopoietic system |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Water flush promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH Up to 5 ppm: (APF = 10) Any supplied-air respirator* Up to 12.5 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* Up to 25 ppm: (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Up to 500 ppm: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode* Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 0060 See MEDICAL TESTS: 0096 |