1-Hexadecanethiol |
Synonyms & Trade Names Cetyl mercaptan, Hexadecanethiol-1, n-Hexadecanethiol, Hexadecyl mercaptan |
CAS No. 2917-26-2 |
RTECS No. |
DOT ID & Guide 1228 131 (liquid) |
FormulaCH3[CH2]15SH |
Conversion 1 ppm = 10.59 mg/m3 |
IDLH N.D. See: IDLH INDEX |
Exposure Limits NIOSH REL: C 0.5 ppm (5.3 mg/m3) [15-minute] OSHA PEL: none |
Measurement Methods None available See: NMAM or OSHA Methods |
Physical Description Colorless liquid or solid (below 64-68°F) with a strong odor. |
MW: 258.5 |
BP: ? |
FRZ: 64-68°F |
Sol: Insoluble |
VP: 0.1 mmHg |
IP: ? |
Sp.Gr: 0.85 |
Fl.P: 215°F |
UEL: ? |
LEL: ? |
|
|
| Class IIIB Combustible Liquid: Fl.P. at or above 200°F. |
Incompatibilities & Reactivities Oxidizers, strong acids & bases, alkali metals, reducing agents |
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact |
Symptoms irritation eyes, skin, respiratory system; headache, dizziness, lassitude (weakness, exhaustion), cyanosis, nausea, convulsions |
Target Organs Eyes, skin, respiratory system, central nervous system, blood |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH Up to 5 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s) (APF = 10) Any supplied-air respirator Up to 12.5 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s) Up to 25 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 0025
|