Hexone

Synonyms & Trade Names
Isobutyl methyl ketone, Methyl isobutyl ketone, 4-Methyl 2-pentanone, MIBK
CAS No.
108-10-1
RTECS No.
SA9275000
DOT ID & Guide
1245 127
Formula
CH3COCH2CH(CH3)2
Conversion
1 ppm = 4.10 mg/m3
IDLH
500 ppm
See: 108101
Exposure Limits
NIOSH REL
: TWA 50 ppm (205 mg/m3) ST 75 ppm (300 mg/m3)
OSHA PEL
: TWA 100 ppm (410 mg/m3)
Measurement Methods

NIOSH 1300 , 2555;
OSHA 1004
See: NMAM or OSHA Methods
Physical Description
Colorless liquid with a pleasant odor.
MW:
100.2
BP:
242°F
FRZ:
-120°F
Sol:
2%
VP:
16 mmHg
IP:
9.30 eV
Sp.Gr:
0.80
Fl.P:
64°F
UEL(200°F): 8.0% LEL(200°F): 1.2%
Class IB Flammable Liquid: Fl.P. below 73°F and BP at or above 100°F.
Incompatibilities & Reactivities
Strong oxidizers, potassium tert-butoxide
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, mucous membrane; headache, narcosis, coma; dermatitis; in animals: liver, kidney damage
Target Organs
Eyes, skin, respiratory system, central nervous system, liver, kidneys
Personal Protection/Sanitation
(See protection codes)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet (flammable)
Change: No recommendation
First Aid
(See procedures)
Eye: Irrigate immediately
Skin: Water flush promptly
Breathing: Respiratory support
Swallow: Medical attention immediately
Respirator Recommendations

NIOSH

Up to 500 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)*
(APF = 10) Any supplied-air respirator*
(APF = 50) Any self-contained breathing apparatus with a full facepiece

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also: INTRODUCTION   See ICSC CARD: 0511   See MEDICAL TESTS: 0134
Syndicated Content Details:
Source URL: http://www.cdc.gov/niosh/z-lab-945/npg-syndicate/npgd0326.html
Source Agency: Centers for Disease Control and Prevention (CDC)
Captured Date: 2016-05-23 21:58:18.0

 

 

 

 

Terms of Use | Privacy Policy
©2017 ARCHES Technology. All Rights Reserved.