Boron oxide

Synonyms & Trade Names
Boric anhydride, Boric oxide, Boron trioxide
CAS No.
1303-86-2
RTECS No.
ED7900000
DOT ID & Guide
Formula
B2O3
Conversion
IDLH
2000 mg/m3
See: 1303862
Exposure Limits
NIOSH REL
: TWA 10 mg/m3
OSHA PEL
: TWA 15 mg/m3
Measurement Methods

NIOSH 0500
See: NMAM or OSHA Methods
Physical Description
Colorless, semitransparent lumps or hard, white, odorless crystals.
MW:
69.6
BP:
3380°F
MLT: 842°F
Sol:
3%
VP:
0 mmHg (approx)
IP:
13.50 eV
Sp.Gr:
2.46
Fl.P:
NA
UEL:
NA
LEL:
NA
Noncombustible Solid
Incompatibilities & Reactivities
Water [Note: Reacts slowly with water to form boric acid.]
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, respiratory system; cough; conjunctivitis; skin erythema (skin redness)
Target Organs
Eyes, skin, respiratory system
Personal Protection/Sanitation
(See protection codes)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet or contaminated
Change: No recommendation
First Aid
(See procedures)
Eye: Irrigate immediately
Skin: Water flush promptly
Breathing: Fresh air
Swallow: Medical attention immediately
Respirator Recommendations

NIOSH

Up to 50 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.*

Up to 100 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*

Up to 250 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*

Up to 500 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 2000 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also: INTRODUCTION   See ICSC CARD: 0836
Syndicated Content Details:
Source URL: http://www.cdc.gov/niosh/z-lab-945/npg-syndicate/npgd0060.html
Source Agency: Centers for Disease Control and Prevention (CDC)
Captured Date: 2016-05-23 21:58:20.0

 

 

 

 

Terms of Use | Privacy Policy