Tetramethyl succinonitrile |
Synonyms & Trade Names Tetramethyl succinodinitrile, TMSN |
CAS No. 3333-52-6 |
RTECS No. WN4025000 |
DOT ID & Guide |
Formula(CH3)2C(CN)C(CN)(CH3)2 |
Conversion 1 ppm = 5.57 mg/m3 |
IDLH 5 ppm See: 3333526 |
Exposure Limits NIOSH REL: TWA 3 mg/m3 (0.5 ppm) [skin] OSHA PEL: TWA 3 mg/m3 (0.5 ppm) [skin] |
Measurement Methods NIOSH S155 (II-3); OSHA 7 See: NMAM or OSHA Methods |
Physical Description Colorless, odorless solid. [Note: Forms cyanide in the body.] |
MW: 136.2 |
BP: Sublimes |
MLT: 338°F (Sublimes) |
Sol: Insoluble |
VP: ? |
IP: ? |
Sp.Gr: 1.07 |
Fl.P: ? |
UEL: ? |
LEL: ? |
|
|
| Combustible Solid |
Incompatibilities & Reactivities Strong oxidizers |
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact |
Symptoms headache, nausea; convulsions, coma; liver, kidney, gastrointestinal effects |
Target Organs central nervous system, liver, kidneys, gastrointestinal tract |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH/OSHA Up to 28 mg/m3: (APF = 10) Any supplied-air respirator (APF = 50) Any self-contained breathing apparatus with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 1121
|