Ethyl butyl ketone |
Synonyms & Trade Names Butyl ethyl ketone, 3-Heptanone |
CAS No. 106-35-4 |
RTECS No. MJ5250000 |
DOT ID & Guide 1224 127 |
FormulaCH3CH2CO[CH2]3CH3 |
Conversion 1 ppm = 4.67 mg/m3 |
IDLH 1000 ppm See: 106354 |
Exposure Limits NIOSH REL: TWA 50 ppm (230 mg/m3) OSHA PEL: TWA 50 ppm (230 mg/m3) |
Measurement Methods NIOSH 1301 , 2553; OSHA 7 See: NMAM or OSHA Methods |
Physical Description Colorless liquid with a powerful, fruity odor. |
MW: 114.2 |
BP: 298°F |
FRZ: -38°F |
Sol: 1% |
VP: 4 mmHg |
IP: 9.02 eV |
Sp.Gr: 0.82 |
Fl.P(oc): 115°F |
UEL: ? |
LEL: ? |
|
|
| Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F. |
Incompatibilities & Reactivities Oxidizers, acetaldehyde, perchloric acid |
Exposure Routes inhalation, ingestion, skin and/or eye contact |
Symptoms irritation eyes, skin, mucous membrane; headache, narcosis, coma; dermatitis |
Target Organs Eyes, skin, respiratory system, central nervous system |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Water flush Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH/OSHA Up to 500 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)* (APF = 10) Any supplied-air respirator* Up to 1000 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode* (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)* (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 0889
|