o-Dianisidine |
Synonyms & Trade Names Dianisidine; 3,3'-Dianisidine; 3,3'-Dimethoxybenzidine |
CAS No. 119-90-4 |
RTECS No. DD0875000 |
DOT ID & Guide |
Formula(NH2C6H3OCH3)2 |
Conversion |
IDLH Ca [N.D.] See: IDLH INDEX |
Exposure Limits NIOSH REL: Ca See Appendix A See Appendix C OSHA PEL: See Appendix C |
Measurement Methods NIOSH 5013; OSHA 71 See: NMAM or OSHA Methods |
Physical Description Colorless crystals that turn a violet color on standing. [Note: Used as a basis for many dyes.] |
MW: 244.3 |
BP: ? |
MLT: 279°F |
Sol: Insoluble |
VP: ? |
IP: ? |
Sp.Gr: ? |
Fl.P: 403°F |
UEL: ? |
LEL: ? |
|
|
| Combustible Solid |
Incompatibilities & Reactivities Oxidizers |
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact |
Symptoms irritation skin; in animals: kidney, liver damage; thyroid, spleen changes; [potential occupational carcinogen] |
Target Organs Skin, kidneys, liver, thyroid, liver |
Cancer Site[in animals: bladder, liver, stomach & mammary gland tumors] |
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated/Daily Remove: When wet or contaminated Change: Daily Provide: Eyewash, Quick drench |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters. Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 1582
|