Methylcyclohexane |
Synonyms & Trade Names Cyclohexylmethane, Hexahydrotoluene |
CAS No. 108-87-2 |
RTECS No. GV6125000 |
DOT ID & Guide 2296 128 |
FormulaCH3C6H11 |
Conversion 1 ppm = 4.02 mg/m3 |
IDLH 1200 ppm [LEL] See: 108872 |
Exposure Limits NIOSH REL: TWA 400 ppm (1600 mg/m3) OSHA PEL†: TWA 500 ppm (2000 mg/m3) |
Measurement Methods NIOSH 1500; OSHA 7 See: NMAM or OSHA Methods |
Physical Description Colorless liquid with a faint, benzene-like odor. |
MW: 98.2 |
BP: 214°F |
FRZ: -196°F |
Sol: Insoluble |
VP: 37 mmHg |
IP: 9.85 eV |
Sp.Gr: 0.77 |
Fl.P: 25°F |
UEL: 6.7% |
LEL: 1.2% |
|
|
| Class IB Flammable Liquid: Fl.P. below 73°F and BP at or above 100°F. |
Incompatibilities & Reactivities Strong oxidizers |
Exposure Routes inhalation, ingestion, skin and/or eye contact |
Symptoms irritation eyes, skin, nose, throat; dizziness, drowsiness; in animals: narcosis |
Target Organs Eyes, skin, respiratory system, central nervous system |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet (flammable) Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH Up to 1200 ppm: (APF = 10) Any supplied-air respirator (APF = 50) Any self-contained breathing apparatus with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 0923
|