1-Octanethiol |
Synonyms & Trade Names 1-Mercaptooctane, n-Octyl mercaptan, Octylthiol, 1-Octylthiol |
CAS No. 111-88-6 |
RTECS No. |
DOT ID & Guide 1228 131 |
FormulaCH3(CH2)7SH |
Conversion 1 ppm = 5.98 mg/m3 |
IDLH N.D. See: IDLH INDEX |
Exposure Limits NIOSH REL: C 0.5 ppm (3.0 mg/m3) [15-minute] OSHA PEL: none |
Measurement Methods NIOSH 2510 See: NMAM or OSHA Methods |
Physical Description Water-white liquid with a mild odor. |
MW: 146.3 |
BP: 390°F |
FRZ: -57°F |
Sol: Insoluble |
VP(212°F): 3 mmHg |
IP: ? |
Sp.Gr: 0.84 |
Fl.P(oc): 115°F |
UEL: ? |
LEL: ? |
|
|
| Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F. |
Incompatibilities & Reactivities Oxidizers, reducing agents, strong acids & bases, alkali metals |
Exposure Routes inhalation, ingestion, skin and/or eye contact |
Symptoms irritation eyes, skin, nose, throat; lassitude (weakness, exhaustion), cyanosis, increased respiration, nausea, drowsiness, headache, vomiting |
Target Organs Eyes, skin, respiratory system, blood, central nervous system |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH Up to 5 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s) (APF = 10) Any supplied-air respirator Up to 12.5 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s) Up to 25 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 1493
|