Cyclohexene |
Synonyms & Trade Names Benzene tetrahydride, Tetrahydrobenzene |
CAS No. 110-83-8 |
RTECS No. GW2500000 |
DOT ID & Guide 2256 130 |
FormulaC6H10 |
Conversion 1 ppm = 3.36 mg/m3 |
IDLH 2000 ppm See: 110838 |
Exposure Limits NIOSH REL: TWA 300 ppm (1015 mg/m3) OSHA PEL: TWA 300 ppm (1015 mg/m3) |
Measurement Methods NIOSH 1500; OSHA 7 See: NMAM or OSHA Methods |
Physical Description Colorless liquid with a sweet odor. |
MW: 82.2 |
BP: 181°F |
FRZ: -154°F |
Sol: Insoluble |
VP: 67 mmHg |
IP: 8.95 eV |
Sp.Gr: 0.81 |
Fl.P: 11°F |
UEL: ? |
LEL: ? |
|
|
| Class IB Flammable Liquid: Fl.P. below 73°F and BP at or above 100°F. |
Incompatibilities & Reactivities Strong oxidizers [Note: Forms explosive peroxides with oxygen upon storage.] |
Exposure Routes inhalation, ingestion, skin and/or eye contact |
Symptoms irritation eyes, skin, respiratory system; drowsiness |
Target Organs Eyes, skin, respiratory system, central nervous system |
|
Personal Protection/Sanitation (See protection codes) Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet (flammable) Change: No recommendation |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations NIOSH/OSHA Up to 2000 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode£ (APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)£ (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister (APF = 50) Any self-contained breathing apparatus with a full facepiece (APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode (APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister Any appropriate escape-type, self-contained breathing apparatus Important additional information about respirator selection |
| See also: INTRODUCTION See ICSC CARD: 1054
|