Ethylene glycol dinitrate

Synonyms & Trade Names
EGDN; 1,2-Ethanediol dinitrate; Ethylene dinitrate; Ethylene nitrate; Glycol dinitrate; Nitroglycol
CAS No.
628-96-6
RTECS No.
KW5600000
DOT ID & Guide
Formula
O2NOCH2CH2ONO2
Conversion
1 ppm = 6.22 mg/m3
IDLH
75 mg/m3
See: 628966
Exposure Limits
NIOSH REL
: ST 0.1 mg/m3 [skin]
OSHA PEL
: C 0.2 ppm (1 mg/m3) [skin]
Measurement Methods

NIOSH 2507;
OSHA 43
See: NMAM or OSHA Methods
Physical Description
Colorless to yellow, oily, odorless liquid. [Note: An explosive ingredient (60-80%) in dynamite along with nitroglycerine (40-20%).]
MW:
152.1
BP:
387°F
FRZ:
-8°F
Sol:
Insoluble
VP:
0.05 mmHg
IP:
?
Sp.Gr:
1.49
Fl.P:
419°F
UEL:
?
LEL:
?
Explosive Liquid
Incompatibilities & Reactivities
Acids, alkalis
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
throbbing headache; dizziness; nausea, vomiting, abdominal pain; hypotension, flush, palpitations, angina; methemoglobinemia; delirium, central nervous system depression; irritation skin; in animals: anemia; liver, kidney damage
Target Organs
Skin, cardiovascular system, blood, liver, kidneys
Personal Protection/Sanitation
(See protection codes)
Skin: Prevent skin contact
Eyes: Prevent eye contact
Wash skin: When contaminated
Remove: When wet (flammable)
Change: Daily
Provide: Quick drench
First Aid
(See procedures)
Eye: Irrigate immediately
Skin: Soap wash immediately
Breathing: Respiratory support
Swallow: Medical attention immediately
Respirator Recommendations

NIOSH

Up to 1 mg/m3:
(APF = 10) Any supplied-air respirator*

Up to 2.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*

Up to 5 mg/m3:
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 75 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also: INTRODUCTION   See ICSC CARD: 1056   See MEDICAL TESTS: 0105
Syndicated Content Details:
Source URL: http://www.cdc.gov/niosh/z-lab-945/npg-syndicate/npgd0273.html
Source Agency: Centers for Disease Control and Prevention (CDC)
Captured Date: 2016-05-23 22:00:43.0

 

 

 

 

Terms of Use | Privacy Policy